Output Voltage |
Zero to rated voltage
continuously variable with front panel voltage knob |
Output Current |
Zero to rated current
continuously variable with front panel current knob |
Line Regulation |
CV±0.01%+2mV; CC±0.01%+2mA |
Load Regulation |
CV±0.01%+2mV; CC<10mA @
100W;<15mA @ above 100W |
Ripple & Noise |
CV<0.5mVrms @ 100W;
<1mVrms @ above 100W
CC<1mArms @ 100W; <3mArms @ above 100W |
Transient Response |
<100µS to within 0.1% of
set voltage (50% to 100% load change) |
Output Impedance |
<2mW +2mH |
Operating Range |
0 to 40° C ambient
temperature |
Display Accuracy |
£ 0.1%+2 digits |
Overload Protection |
Automatic crossover from CV to
CC mode |
Series Connection |
Different models can be
chained to increase output up to 240 Vdc |
Parallel Connection |
Another same model can be
paralleled to increase output to 24 Amps |
Power Requirement |
100/120/220/240±10% Vac;
50/60Hz single phase |
Accessories Supplied |
Power cord; hook-up leads;
instruction manual |