DC VOLTAGE MEASUREMENT |
Range |
± 199.9mV, ± 1.999V, ± 19.99V,
± 199.9V, ± 1200V, 5 Ranges |
Accuracy |
± (0.1% + 1d) |
Input Impedance |
10MW |
AC VOLTAGE MEASUREMENT
(AC or AC + DC TrueRMS) |
Range |
± 199.9mV, ± 1.999V, ± 19.99V,
± 199.9V, ± 1000V, 5 Ranges |
Accuracy |
199.9mV ~ 199.9V 4 Ranges 45Hz~
2KHz ± (0.5%+1d), 2KHz~ 10KHz
± (1%+1d), 10KHz~ 20KHz ± (2%+1d),
20KHz~ 50KHz~ 50KHz ± (5%+2d), 1000V Range
45Hz-1KHz ± (0.5%+2d) |
Input Impedance |
10MW // 100pF |
DC CURRENT MEASUREMENT |
Range |
± 199.9mA, ± 1.999mA, ±
19.99mA, ± 199.9mA, ± 1999mA, ±
19.99A, 6 Ranges |
Accuracy |
199.9mA ~ 199.9mA 4 Ranges ±
(0.2%+1d), 1999mA ~ 19.99A 2
Ranges ± (0.3%+1d), |
Protection |
2A 250V DC or RMS [Fuse Protected]
for 199.9m A ~ 1999mA |
AC CURRENT MEASUREMENT
(AC or AC+DC TrueRMS) |
Range |
199.9mA, 1.999mA, 19.99mA,
199.9mA, 1999mA, 19.99A, 6 Ranges |
Accuracy |
199.9mV ~ 199.9mA 4 Ranges 45Hz~
2KHz ± (0.5%+1d), 2KHz~ 10KHz
± (1%+1d), 10KHz~ 20KHz ± (2%+1d),
1999mA ~ 19.99A 2 Range 45Hz~ 2KHz ± (0.5%+1d) |
Protection |
2A 250V DC or RMS [Fuse Protected]
for 199.9mA ~ 1999mA |
OHM MEASUREMENT |
Range |
199.9W , 1.999k, 1.999kW , 19.99KW
199.9KW , 1.999MW , 19.99MW , 6
Ranges |
Accuracy |
199.9W range ± (0.1% +1d) 1.999KW ~ 1.999MW 4 Ranges ± (0.1% +1d)
19.99MW Range ± (0.25% +2d) |
DIODE TEST |
YES |
GENERAL |
Display |
0.5", 3 ½ Digits Green LED
Display |
Power Source |
ACV 115V/230V, ± 10%, 60Hz/50Hz |
Dimension |
262 (W) x 85 (H) x 260 (D) mm |
Gross Weight |
1.5kg |
Accessories |