| Output Voltage |
Zero to rated voltage
continuously variable with front panel voltage knob |
| Output Current |
Zero to rated current
continuously variable with front panel current knob |
| Line Regulation |
CV±0.01%+2mV;
CC±0.01%+2mA |
| Load Regulation |
CV±0.01$+2mV;
CC<10mA @ 100W;<15mA @ above 100W |
| Ripple & Noise |
CV<0.5mVrms @
100W; <1mVrms @ above 100W
CC<1mArms @ 100W; <3mArms @ above 100W |
| Transient Response |
<100µS to within
0.1% of set voltage (50% to 100% load change) |
| Output Impedance |
<2mW +2mH |
| Operating Range |
0 to 40° C ambient
temperature |
| Display Accuracy |
3% of full scale |
| Overload Protection |
Automatic crossover
from CV to CC mode |
| Series Connection |
Different models can
be chained to increase output up to 240 Vdc |
| Parallel Connection |
Another same model
can be paralleled to increase output to 24 Amps |
| Power Requirement |
100/120/220/240±10%
Vac; 50/60Hz single phase |
| Accessories Supplied |
Power cord; hook-up
leads; instruction manual |