Output Voltage |
Zero to rated voltage
continuously variable with front panel voltage knob |
Output Current |
Zero to rated current
continuously variable with front panel current knob |
Line Regulation |
CV±0.01%+2mV;
CC±0.01%+2mA |
Load Regulation |
CV±0.01$+2mV;
CC<10mA @ 100W;<15mA @ above 100W |
Ripple & Noise |
CV<0.5mVrms @
100W; <1mVrms @ above 100W
CC<1mArms @ 100W; <3mArms @ above 100W |
Transient Response |
<100µS to within
0.1% of set voltage (50% to 100% load change) |
Output Impedance |
<2mW +2mH |
Operating Range |
0 to 40° C ambient
temperature |
Display Accuracy |
3% of full scale |
Overload Protection |
Automatic crossover
from CV to CC mode |
Series Connection |
Different models can
be chained to increase output up to 240 Vdc |
Parallel Connection |
Another same model
can be paralleled to increase output to 24 Amps |
Power Requirement |
100/120/220/240±10%
Vac; 50/60Hz single phase |
Accessories Supplied |
Power cord; hook-up
leads; instruction manual |